Delta PD-01 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Delta PD-01. Delta PD-01 User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Profibus (CME-PD01)
User Manual
Profibus is a registered trademark of Profibus International.
The information supplied by this document is subject to change without notice. No
responsibility or liability for the correctness of the information supplied within this
document is assumed.
Vue de la page 0
1 2 3 4 5 6 ... 34 35

Résumé du contenu

Page 1 - User Manual

Profibus (CME-PD01) User Manual Profibus is a registered trademark of Profibus International. The information supplied by this document is sub

Page 2

Chapter 3 Profibus Introduction| CME-PD01 3-2 Revision October 2006, 2006PDD230000133.2 PROFIBUS-DP PROFIBUS-DP is a PROFIBUS communication profile o

Page 3 -

Revision October 2006, 2006PDD23000013 4-1 Chapter 4 Installation Information Please make sure that the power of VFD-E series is OFF before installa

Page 4

Chapter 4 Installation Information| CME-PD01 4-2 Revision October 2006, 2006PDD23000013 Power Supply The power of CME-PD01 is supplied from VFD-E se

Page 5 - Chapter 1 Preface

Revision October 2006, 2006PDD23000013 5-1 Chapter 5 Communication Please make sure that you have read chapter 4 and fully understood the CME-PD01 i

Page 6 - Chapter 1 Preface

Chapter 5 Communication| CME-PD01 5-2 Revision October 2006, 2006PDD23000013 VFD-E type Baud Rate 9600 P09-01=1 RTU 8, N, 2 P09-03=3 Freq. Source

Page 7 - Chapter 2 Overview

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-3NOTE CME-PD01 supports PPO1 and PPO3 structure only. 5.3.2 Extended Con

Page 8 - 2.3 Functionality

Chapter 5 Communication| CME-PD01 5-4 Revision October 2006, 2006PDD23000013 11B:Change direction 00B:1st Accel / Decel time Bit 6~701B:2nd Accel / D

Page 9 - 3.1 PROFIBUS

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-5NOTE Table above is for reference only, please check VFD-E series user m

Page 10 - 3.2 PROFIBUS-DP

Chapter 5 Communication| CME-PD01 5-6 Revision October 2006, 2006PDD23000013Fault numbers for "Cannot process request" response NO. Descri

Page 11 - 4.1 Installation

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-7NOTE In IND, Bit 15 uses a multiplier of 20, so the value of Bit 15 for

Page 12

Table of Contents Chapter 1 Preface ...1-1 1.1 Receiving and Ins

Page 13 - Chapter 5 Communication

Chapter 5 Communication| CME-PD01 5-8 Revision October 2006, 2006PDD23000013 Request Response Word 1 (PKE) 11C2 Word 1 (PKE) 11C2 Word 2 (IND)

Page 14

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-9in decimal, if set Page Select to 14, then the Basic PNU is 29952-14*200

Page 15 - 5.3.2 Extended Configuration

Chapter 5 Communication| CME-PD01 5-10 Revision October 2006, 2006PDD23000013 T1: transmission time between Master and CME-PD01  T2: waiting time f

Page 16

Revision October 2006, 2006PDD23000013 6-1 Chapter 6 Parameters Setting in GSD file 6.1 GSD File A GSD file is a text file used to identify PROFIBUS

Page 17 - 5.3.5.1 PKE

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-2 Revision October 2006, 2006PDD23000013 Auto_Baud_supp = 1 9.6_supp = 1 19

Page 18 - 5.3.5.2 IND

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-3 0x00,0x00,\

Page 19

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-4 Revision October 2006, 2006PDD23000013Unsigned16 0x0000 0-65535 EndExtUserPrmData ExtUserPrmD

Page 20

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-5 Ext_User_Prm_Data_Ref(10) = 6 Ext_User_Prm_Data_Ref(12)

Page 21 - 5.4 CME-PD01 Response Time

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-6 Revision October 2006, 2006PDD23000013Item Name Type Description Default8 Data Output 4

Page 22

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-7 Data Output 4 = 0x2103; dout_len = 0x0003; The MOD

Page 23 - 6.1 GSD File

5.3.5 Accessing Parameters via PKW Area... 5-5 5.3.5.1 PKE...

Page 24

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-8 Revision October 2006, 2006PDD23000013This page intentionally left blank

Page 25

Revision October 2006, 2006PDD23000013 7-1 Chapter 7 Troubleshooting 7.1 LED Displays Two LEDs, SP and NET LED, are used to monitor the CME-PD01 co

Page 26

Chapter 7 Troubleshooting| CME-PD01 7-2 Revision October 2006, 2006PDD23000013  SP LED State Indication Corrective Actions LED is off No power 1

Page 27 - 6.2 Parameters Settings

Chapter 7 Troubleshooting| CME-PD01 Revision October 2006, 2006PDD23000013 7-3 00 – Normal 01 – CRC check error 02 – VFD-E returns error code 03 – Co

Page 28

Chapter 7 Troubleshooting| CME-PD01 7-4 Revision October 2006, 2006PDD23000013 Error Code Description Corrective Actions 01 Illegal command code

Page 29

Revision October 2006, 2006PDD23000013 8-1 Chapter 8 Dimensions 57.3[2.26]59.7[2.35]3.6[0.14]72.2 [2.84]3.5 [0.14]34.8 [1.37]ADDH ADDLSPNETCME-PB0

Page 31 - Chapter 7 Troubleshooting

Revision October 2006, 2006PDD23000013 1-1 Chapter 1 Preface 1.1 Receiving and Inspection All Delta CME-PD01 have gone through rigorous quality cont

Page 32 - 7.2 Diagnostic Data

Chapter 1 Preface| CME-PD01 1-2 Revision October 2006, 2006PDD23000013 This page intentionally left blank

Page 33 - 7.3 Error Codes

Revision October 2006, 2006PDD23000013 2-1 Chapter 2 Overview CME-PD01, defined as a communication module for PROFIBUS-DP, is used to link VFD-E ser

Page 34

Chapter 2 Overview| CME-PD01 2-2 Revision October 2006, 2006PDD23000013 The address in PROFIBUS-DP can be set via two rotary address switches, ADDH

Page 35 - Chapter 8 Dimensions

Revision October 2006, 2006PDD23000013 3-1 Chapter 3 Profibus Introduction 3.1 PROFIBUS PROFIBUS is an international, vendor- independent, opening

Commentaires sur ces manuels

Pas de commentaire