SECTION 5: SERVICE PROCEDURES
REPLACING THE CHEMICAL FEEDER PUMP MOTOR (CONTINUED)
19
14. Place the roller and the rubber tube back in the pump cas-
ing. Place the pump cover back on and tighten down with the
four screws you previously removed.
15. Reattach the power wire and the wire for the priming
switch.
16. Put the cover back on the control box and secure with the
two screws previously removed.
17. Ensuring that all non-essential personnel are clear of the
area, restore power to the unit. Turn the unit on and by using
the priming switch, verify that the feeder pump operates and
pumps fluid.
18. Replace the front door.
AFTER MAINTENANCE ACTIONS
None.
SPECIAL NOTES
Work performed on Jackson dishmachines by unau-
thorized or unqualified personnel may void the warranty.
Before beginning this or any other maintenance evolution on a
unit under warranty, you should contact a certified Jackson
technician or Jackson Technical Service. You can find a list of
qualified service agencies in the back of you unit’s installation
manual.
SPECIAL PARTS
Removing the motor mounting screws.
Removing the motor.
Removing the roller.